Residential Standards of Practice      Call 518-505-8305


Table of Contents

1. Definitions and Scope.

2. Standards of Practice

       2.1. Roof
        2.2. Exterior
        2.3. Basement, Foundation,
               Crawlspace
        2.4. Heating
        2.5. Cooling
        2.6. Plumbing
        2.7. Electrical
        2.8. Fireplace
        2.9. Attic & Insulation
        2.10. Doors, Windows, & Interior


3. Limitations, Exceptions &
    Exclusions






1. Definitions and Scope

        1.1. A Home Inspection is a non-invasive, visual examination of a residential dwelling, performed for a fee, which is designed to identify observed material defects within specific components of said dwelling. Components may include any combination of mechanical, structural, electrical, plumbing, or other essential systems of portions of the home, as identified and agreed to by the Client and Inspector, prior to the inspection process.

                 I. A home inspection is intended to assist in evaluation of the overall condition of the
                 dwelling. The inspection is based on observation of the visible and apparent condition
                 of the structure and its components on the date of the inspection, and not the prediction
                 of future conditions.

                 II. A home inspection will not reveal every concern that exists or ever could exist,but
                 only those material defects observed on the date of the inspection.
      
       1.2 A Material Defect is a condition of a residential real property, or any portion of it, that would have a significant, adverse impact on the value of the real property, or that involves an unreasonable risk to people on the property. The fact that a structural element, system or subsystem is near, at or beyond the end of the normal useful life of such a structural element, system or subsystem is not by itself a material defect.

       1.3. An Inspection Report shall describe and identify, in written format, the inspected systems, structures, and components of the dwelling, and shall identify material defects observed. Inspection reports may contain recommendations regarding conditions reported or recommendations for correction, monitoring or further evaluation by professionals, but this is not required.


2. Standards of Practice

       2.1. Roof
 
                 I. The inspector shall inspect from ground level or eaves:                                                                      
                          
                           A. the roof covering;
                           B. the gutters;
                           C. the downspouts;
                           D. the vents, flashings, skylights, chimney and other roof penetrations; and
                           E. the general structure of the roof from the readily accessible panels, doors or stairs.

                 II. The inspector is not required to:
                         
                           A. walk on any pitched roof surface.
                           B. predict the service life expectancy.
                           C. inspect underground downspout diverter drainage pipes.
                           D. remove snow, ice, debris or other conditions that prohibit the observation of the roof surfaces.
                           E. move insulation.
                           F. inspect antennae, lighting arresters, de-icing equipment, or similar attachments.
                           G. walk on any roof areas that appear, in the opinion of the inspector, to be unsafe.
                           H. walk on any roof areas if it might, in the opinion of the inspector, cause damage.
                            I. perform a water test.
                            J. warrant or certify the roof.

       
       2.2. Exterior

                 I. The inspector shall inspect:
                        
                           A. the siding, flashing and trim;
                           B. all exterior doors, decks, stoops, steps, stairs, porches, railings, eaves, soffits and fascias;
                           C. and report as in need of repair any spacings between intermediate balusters, spindles, or rails for
                                steps, stairways balconies, and railings  that permit the passage of an object greater that 4 inches in
                               diameter;    
                           D. a representative number of windows;
                           E. the vegetation, surface drainage, and retaining walls when these are likely to adversely affect the
                              structure;
                           F. and describe the exterior wall covering.

               II. The inspector is not required to:

                           A. inspect or operate screens, storm windows, shutters, awnings, fences, outbuildings, or exterior accent
                                lighting.
                           B. inspect items, including window and door flashings, which are not visible or readily accessable from
                                the ground.
                           C. inspect geological, geotechnical, hydrological and/or soil conditions.
                           D. inspect recreational facilities or playground equipment.
                           E. inspect seawalls, break-walls and docks.
                           F. inspect erosion control and earth stabilization measures.
                           G. inspect for safety-type glass
                           H. inspect underground utilities.
                           I. inspect underground items.
                           J. inspect wells or springs.
                           K.inspect solar, wind, or geothermal systems.
                           L. inspect swimming pools or spas.
                           M. inspect septic systems or cesspools.
                           N. inspect sprinkler systems.
                           O. inspect drain fields or drywells.
                           P. determine the integrity of the thermal window seals or damage glass.


        2.3. Basement, Foundation & Crawlspace

                 I. The inspector shall inspect:
                         
                           A. the basement;
                           B. the foundation;
                           C. the crawlspace;
                           D. the visible structural components;
                           E. and report on the location of under-floor access openings;
                           F. and report any present conditions or clear indications of active water penetration observed by the
                               inspector
                          G. for wood in contact or near soil;
                          H. and report any general indications of foundation movement that are observed by the inspector, such
                               as, but not limited to sheetrock cracks, brick cracks, out-of-square door frames, or floor slopes;
                          I. and report on any cutting, notching and boring of framing members which may present a structural or
                             safety concern.
                            
                II. The inspector is not required to:

                          A. enter any crawlspaces that are not readily accessible or where entry could cause damage or pose a
                               hazard to the inspector.
                          B. move stored items or debris.
                          C. operate sump pumps with inaccessible floats.
                          D. identify size, spacing, span, location or determine adequacy of foundation bolting, bracing, joists, joist
                              spans or support systems.
                          E. provide any engineering or architectural service.
                          F. report on the adequacy of any structural system or component.


                      

               
          



        2.4 Heating

                 I. The inspector shall inspect:

                           A. the heating systems using normal operating controls, and describe the energy source and  heating
                               method;
                           B. and report as in need or repair heating systems which do not operate;
                           C. and report if the heating systems are deemed inaccessible.

                II. The inspector is not required to:

                           A. inspect or evaluate interiors of flues or chimneys, fire chambers, heat exchangers, combustion air
                                systems, fresh air intakes, humidifiers, dehumidifiers, electronic air filters, geothermal systems or
                                solar heating systems.
                           B. inspect fuel tanks or underground or concealed fuel supply systems.
                           C. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply
                                adequacy of the heating system.
                           D. light or ignite pilot flames.
                           E. activate heating, heat pump systems or other heating systems when ambient temperatures or other
                               circumstances are not conducive to safe operation or may damage the equipment.
                           F. override electronic thermostats.
                           G. evaluate fuel quality.
                           H. verify thermostat calibration, heat anticipation, or automatic setbacks, timers, programs or clocks.

        2.5 Cooling

                 I. The inspector shall inspect:          

                          A. the central cooling equipment using normal operating controls.

                II. The inspector is not required to:

                          A. determine the uniformity, temperature, flow, balance, distribution, size, capacity, BTU, or supply
                               adequacy of the cooling system.
                          B. inspect window units, through-wall units, or air filters.
                          C. operate equipment or systems if exterior temperature is below 60 degrees Fahrenheit, or when other
                               circumstances are not conducive to safe operation, or may damage the equipment.
                          D. inspect or determine thermostat calibration, heat anticipation, or automatic setbacks or clocks.
                          E. examine electrical current, coolant fluids or gases, or coolant leakage.






        2.6 Plumbing

                 I. The inspector shall:

                           A. inspect and determine if the water supply is public or private;
                           B. verify the presence of and identify the location of the main water shut-off valve;
                           C. inspect the water heating equipment, including venting, connections, energy source supply
                                system, and seismic bracing, and verify the presence or absence of temperature-pressure relief 
                                valves and/or Watts 210valves;
                           D. flush toilets;
                           E. run water in sinks, tubs, and showers;
                           F. inspect the interior water supply, including all fixtures and faucets;
                           G. inspect the drain, waste and vent systems, including all fixtures;
                           H. describe any visible fuel storage systems;
                           I.  inspect the drainage sump pumps and test pumps with accessible floats;
                           J. inspect and describe the water supply, drain, waste and main fuel shut-off valves, as well as the
                               location of water main and main fuel shut valves;
                          K. inspect and report as in need of repair deficiencies in the water supply by viewing the functional flow in
                               two
                               fixtures operated simultaneously;
                          L. inspect and report as in need of repair deficiencies in installation and identification of hot and cold
                              faucets;
                         M. inspect and report as in need of repair mechanical drain-stops that are missing or do not operate if
                              installed in sinks lavatories and tubs; and
                         N. inspect and report in need of repair commodes that have cracks in the ceramic material, are improperly
                              mounted the floor, leak, or have tank components which do not operate.

                 II. The inspector is not required to:

                           A. light or ignite pilot flames.
                           B. determine the size, temperature, age life expectancy or adequacy of the water heater.
                           C. inspect interiors of flues or chimneys, combustion air systems, water softening or filtering systems,
                                well pumps tanks, safety or shut-off valves, floor drains, lawn sprinkler systems or fire sprinkler systems.
                           D. determine the exact flow rate, volume, pressure, temperature, or adequacy of the water supply.
                           E. determine the water quality or potability or the reliability of the water supply or source.
                           F. open sealed plumbing access panels.
                           G. inspect clothes washing machines or their connections,
                           H. operate any main, branch or fixture valve.
                           I. test shower pans, tub and shower surrounds or enclosures for leakage.
                           J. evaluate the compliance with local or state conservation or energy standards, or the proper design or
                               sizing of any water, waste or venting components, fixtures or piping.
                           K. determine the effectiveness of anti-siphon, back-flow prevention or drain-stop devices.
                           L. determine whether there are sufficient clean-outs for effective cleaning of drains.
                           M. evaluate gas, liquid propane or oil storage tanks.
                           N. inspect any underground or concealed fuel supply systems.
                           O. inspect any private sewage waste disposal systems or component thereof.
                           P. inspect water treatment systems or water filters.
                           Q. inspect water storage tanks, pressure pumps or bladder tanks.
                           R. evaluate wait-time to obtain hot water at fixtures, or perform testing of any kind to water heater
                                elements.
                           S. evaluate or determine the adequacy of combustion air.
                           T. test, operate, open or close safety controls, manual stop valves and/or temperature or pressure relief
                               valves.
                           U. examine ancillary systems or components, such as, but not limited to, those relating to solar water
                                heating hot water circulation,
                           V. determine the existence or condition of polybutylene plumbing.






        2.7 Electrical
                   
                 I. the inspector shall inspect:

                           A. the service drop/lateral;
                           B. the meter socket enclosures;
                           C. the means for disconnecting the service main;
                           D. and describe the service disconnect amperage rating, if labeled;
                           E. panelboards and overcurrent devices (breakers and fuses);
                           F. and report on any unused circuit breaker panel openings that are not filled;
                           G. the service grounding and bonding;
                           H. a representative number of switches, lighting fixtures, and receptacles, including receptacles observed
                                and deemed to be AFCI-protected during the inspection using an AFCI tester, where possible;
                           J. and report the presence of solid conductor aluminum branch circuit wiring, if readily visible;
                           K. and report on any tested receptacles in which power was not present, polarity is incorrect, is not
                                secured to the wall, the cover is not in place, the ground fault circuit interrupter devices are not properly
                                installed or do not operate properly, evidence of arching or excessive heat is present, or where the
                                receptacle is not grounded or is not secured to the wall;
                           L. the service entrance conductors and the condition of the conductor insulation;
                           M. and report the absence of smoke detectors; and
                           N. service entrance cables, and report as in need of repair deficiencies of conductors at weatherheads
                                and clearances from grade or rooftops.

                 II. the inspector is not required to:

                           A. insert any tool, probe or device into the main panelboard, sub-panels, distribution panelboards, or
                                electrical fixtures.
                           B. operate electrical systems that are shut down.
                           C. remove panelboard cabinet covers or dead front covers, if they are not readily accessible.
                           D. operate or reset overcurrent protection devices or overload devices.
                           E. operate non-accessible smoke detectors.
                           F. measure or determine the amperage or voltage of the main service equipment, if not visibly labeled.
                           G. inspect the fire or alarm system and components.
                           H. inspect the ancillary systems or remote control devices.
                           I. activate any electrical systems, or branch circuits which are not energized.
                           J. inspect low-voltage systems, electrical de-icing tapes, swimming pool wiring, or any time-controlled
                              devices.
                           K. verify the service ground.
                           L. inspect private or emergency electrical supply sources, including, but not limited to; generators,
                               windmills, photovoltaic solar collectors, or battery or electrical storage facility.
                           M. inspect spark or lighting arrestors.
                           N. inspect or test de-icing equipment.
                           O. conduct voltage drop calculations.
                           P. determine the accuracy of labeling.
                           Q. inspect exterior accent lighting.


                     

            


             

        2.8 Fireplace

                 I. The inspector shall inspect:
     
                           A. the fireplace, and open and close the damper door, if readily accessible and operable;
                           B. hearth extensions and other permanently installed components;
                           C. and report as in need of repair deficiencies in the lintel, hearth and material surrounding the fireplace,
                                including fireplace opening clearance from visible combustible materials.

                 II. The inspector is not required to:

                           A. inspect the flue or vent systems.
                           B. inspect the interior of chimneys or flues, fire doors or screens, seals or gaskets, or mantels.
                           C. determine the need for a chimney sweep.
                           D. operate gas fireplace inserts.
                           E. light pilot flames.
                           F. determine the appropriateness of any installation.
                           G. inspect automatic fuel-feed devices.
                           H. inspect combustion and/or make-up air devices.
                           I. inspect heat distribution assists, whether gravity controlled or fan-assisted.
                           J. ignite or extinguish fires.
                          K. determine adequacy of draft or draft characteristics.
                           L. move fireplace inserts, stoves, or firebox contents.
                          M. perform a smoke test.
                          N. dismantle or remove any component.
                          O. perform a National Fire Prevention Association (NFPA)-style inspection.
                          P. perform a Phase I fireplace and chimney inspection.



        2.9. Attic, Ventilation & Insulation

                 I. The inspector shall inspect:

                           A. the insulation in unfinished spaces;
                           B. the ventilation of attic spaces;
                           C. mechanical ventilation systems;
                           D. and report on the general absence or lack of insulation in unfinished spaces.

                II. The inspector is not required to:

                           A. enter the attic or any unfinished spaces that are not readily accessible, or where entry could cause
                               damage or pose a safety hazard to the inspector, in his or her opinion.
                           B. to move, touch, or disturb insulation.
                           C. to move, touch or disturb vapor retarders.
                           D. break or otherwise damage the surface finish or weather seal on or around access panels and covers.
                           E. identify the composition or exact R-value of insulation material.
                           F. activate thermostatically operated fans.
                           G. determine the types of materials used in insulation or wrapping of pipes, ducts, jackets, boilers and
                                wiring.
                           H. determine the adequacy of ventilation.







        2.10. Doors, windows & Interior

                 I. The inspector shall:

                           A. open and close a represe3ntive number of doors and windows;
                           B. inspect walls, ceilings, steps, stairways and railings;
                           C. and report as in need of repair any spacing between intermediate balusters, spindles or rails for steps
                                stairways and railings that permit the passage of an object greater than 4 inches in diameter;
                           D. inspect garage doors and garage door openers by operating first by remote (if available0, and then by
                               the installed automatic door control;
                           E. and report as in need or repair any installed electronic sensors that are not operable or not installed at
                               proper heights above the garage door;
                           F. and report as in need of repair any door locks or side ropes that have not been removed or disabled
                               when garage door opener is in use;
                           G. and report as in need of repair any windows that are obviously fogged or display other evidence of
                                broken seals.

                 II. The inspector is not required to:

                           A. inspect paint, wallpaper, window treatments or finish treatments.
                           B. inspect central vacuum systems.
                           C. inspect safety glazing.
                           D. inspect security systems or components.
                           E. evaluate the fastening of countertops, cabinets, sink tops or fixtures.
                           F. move furniture, stored items, or any coverings, such as carpets or rugs, in order to inspect the
                               concealed floor structure.
                           G. move drop-ceiling tiles.
                           H. inspect or move any household appliances.
                           I.  inspect or operate equipment housed in the garage, except as otherwise noted.
                           J. verify or certify safe operation of any auto-reverse or related safety function of a garage door.
                           K.operate or evaluate any security bar release and opening mechanisms, whether interior or exterior,
                               including their compliance with local, state or federal standards.
                           L. operate any system, appliance or component that requires the use of special keys, codes,
                               combinations or devices.
                          M. operate or evaluate self-cleaning oven cycles, tilt guards/latches or signal lights.
                          N. inspect microwave ovens or test leakage from microwave ovens.
                          O. operate or examine any sauna, steam-jenny, kiln, toaster, ice-maker, coffee-maker, can-opener,
                               bread-warmer, blender instant hot water dispenser, or other small, ancillary devices.
                          P. inspect elevators.
                          Q. inspect remote controls.
                          R. inspect appliances.
                          S. inspect items not permanently installed.
                          T. discover firewall compromises.
                          U. examine or operate any above-ground, movable, freestanding, or otherwise non-permanently installed
                               pool/spa, recreational equipment or self-contained equipment.
                          V. come into contact with any pool or spa water in order to determine the system structure or components.
                         W. determine the adequacy of spa jet water force or bubble effect.
                          X.  determine the structural integrity or leakage of a pool or spa.




3. Limitations, Exceptions & Exclusions

         3.1. Limitations:
 
                 I.   An inspection is not technically exhaustive.
                 II.  An inspection will not identify concealed or latent defects.
                 III. An inspection will not deal with aesthetic concerns or what could be deemed maters of taste, cosmetic
                       defects, etc.
                 IV. An inspection will not determine the suitability of the property for any use.
                 V.  An inspection does not determine the market value of the property or its marketability.
                 VI. An inspection does not determine the insurability of the property.
                 VII. An inspection does not determine the advisability or inadvisability of the purchase of the property.
                 VIII. An inspection does not determine the life expectancy of the property or any components or systems
                          therein.
                 IX. These Standards or Practice apply only to homes with four or fewer dwelling units.

        3.2. Exclusions:

                 I. The inspectors are not required to determine:

                           A. property boundary lines or encroachments.
                           B. the condition of any component or system that is not readily accessible.
                           C. the service life expectancy of any component or system.
                           D. the size, capacity, BTU, performance, or efficiency of any component or system.
                           E. the cause or reason of any condition.
                           F. the cause for the need of repair or replacement of any system or component.
                           G. future conditions.
                           H. compliance with codes or regulations.
                           I.  the presence of evidence of rodents, animals or insects.
                           J.  the presence of mold, mildew or fungus.
                           K. the presence of air-borne hazards.
                           L. the presence of birds.
                           M. the presence of other flora or fauna.
                           N. the air quality.
                           O. the existence of asbestos.
                           P. the existence of environmental hazards.
                           Q. the existence of electro-magnetic fields.
                           R. the presence of hazardous materials including, but not limited to, the presence of lead in paint.
                           S. any hazardous waste conditions.
                           T. any manufacturer's recalls or conformance with manufacturer installation, or any information included
                               for consumer protection purposes.
                           U. operating costs of systems.
                           V. replacement or repair cost estimates.
                           W. the acoustical properties of any systems.
                           X. estimates of the cost to operating any given system.
   
                II. The inspectors are not required to operate:
        
                            A. any system that is shut down.
                            B. any system that does not function properly.
                            C. or evaluate low-voltage electrical systems such as, but not limited to:
                                     1. phone lines;
                                     2. cable lines;
                                     3. antennae;
                                     4. lights; or
                                     5. remote controls.
                            D. any systems that does not turn on with the use of normal operating controls.
                            E. any shut-off valves or manual stop valves.
                            F. any electrical disconnect or over current protection devices.
                            G. any alarm systems.
                            H. moisture meters, gas detectors or similar equipment.

               III. The inspectors are not required to:

                            A. move any personal items or other obstructions, such as, but not limited to:
                                    1. throw rugs;
                                    2. furniture;
                                    3. floor or wall coverings;
                                    4. ceiling tiles;
                                    5. window coverings;
                                    6. equipment;
                                    7. plants;
                                    8. ice;
                                    9. debris;
                                    10. snow;
                                    11. water;
                                    12. dirt;
                                    13. foliage; or
                                    14. pets.
                           
                            B. dismantle, open, or uncover any system or component.
                            C. enter or access any area which may, in the opinion of the inspector, be unsafe.
                            D. enter crawlspace or other ares that are unsafe or not readily accessible.
                            E. inspect underground items such as, but not limited to, underground storage tanks or other indications
                                of their presence, whether abandoned or actively used.
                            F. do anything which, in the inspector's opinion, is likely to be unsafe or dangerous to the inspector or
                                others, or damage property, such as, but not limited to: walking on roof surfaces, climbing ladders,
                                entering attic spaces, or negotiating with pets.
                            G. inspect decorative items.
                            H. inspect common elements or ares in multi-unit housing.
                            I. inspect intercoms, speaker systems, radio-controlled security devices, or lawn irrigation systems.
                            J. offer guarantees or warranties.
                            K. offer or perform any engineering services.
                            L. offer or perform any trade or professional service other than home inspection.
                            M. research the history of the property, report on its potential for alteration, modification, extendibility,
                                 or its suitability for a specific or proposed use for occupancy.
                            N. determine the age of construction or installation of any system structure or component of a building,
                                 or differentiate between original construction and subsequent additions, improvements, renovations
                                 or replacements.
                            O. determine the insurability of a property.
                            P. perform or offer Phase 1 environmental audits.
                            Q. inspect on any system or component which is not included in these standards.
                             











Call 518-505-8305
____________________________________________________________________________________________
Providing inspections for the following cities and towns: Albany, Alcove, Allentown, Alplaus, Altamont, Aqueduct, Athens, Averill Park, Ballston Spa, Bellevue, Berlin, Burnt Hills, Buskirk, Cairo, Carman, Catskill, Chatham, Clarksville, Clifton Park, Coeymans, Cohoes, Colonie, Corinth, Coxsackie, Cropseyville, Defreestville, Delanson, Delmar, Duanesburg, Durham, Eagle Bridge, Earlton, East Greenbush, East Nassau, Elnora, Elsmere, Feura Bush, Freehold, Galway, Gansevoort, Ghent, Gifford, Glenmont, Glenville, Grafton, Green Island, Guilderland, Hadley, Halfmoon, Harmon Park, High Mills, Hillsdale, Hoffmans, Hoosick, Hoosick Falls, Hudson, Hunter, Hutchinson Crossing, Jewett, Karmer, Kenwood, Kinderhook, Knox, Lansingburgh, Latham, Leeds, Loudonville, Malta, Mariaville, Maywood, Mechanicville, Medusa, Melrose, Menands, Nassau, New Baltimore, New Lebanon, New Scotland, Newtonville, Niskayuna, Northumberland, Oakdale, Old Chatham, Palenville, Petersburg, Philmont, Pittstown, Poestenkill, Quackenkill, Ravena, Red Mills, Rensselaer, Rensselaerville, Rexford, Rock City, Rotterdam, Round Lake, Saratoga Springs, Schaghticoke, Schenectady, Schodack landing, Schuylerville, Scotia, Selkirk, Slingerlands, Snyders Corner, South Bethleham, Speigletown, Stillwater, Stockport, Stony Point, Stuyvesent, Sycaway, Tamarack, Tannersville, Thompsons Lake, Tomhannock, Troy, Unionville, Ushers, Valatie Vally Falls, Vischer Ferry, Voorheesville, Waterford, Watervliet, West Albany, Westerlo, Westmere, Wilton, Windham, Woodstock, Wynantskill, Wyomanock, and others.